What is GN19-12(C) Indoor AC Disconnect Switch?
GN19-12 and GN19-12C are indoor 12 kV AC disconnect-switch configurations. The published current options span 400–1,250 A; panel geometry and required withstand duty must match the selected model.
Indoor Disconnect & Earthing Switches · Drawing-confirmed project supply
GN19-12(C) indoor disconnect switches provide manual isolation in 12 kV switchgear, with standard and C-type arrangements listed in the catalogue. Current and withstand ratings depend on the exact model; confirm pole spacing, terminal connections, operating mechanism and interlocks against the approved switchgear drawing.
GN19-12(C) indoor disconnect switches provide manual isolation in 12 kV switchgear, with standard and C-type arrangements listed in the catalogue. Current and withstand ratings depend on the exact model; confirm pole spacing, terminal connections, operating mechanism and interlocks against the approved switchgear drawing.
KOVYEL confirms final selection against the approved drawing, interface dimensions, service conditions and purchase specification before quotation and supply. Catalogue references define the product family; the approved project documents remain the controlling basis.
Images show representative configurations. Final construction, marking and packing are confirmed against the approved project documents.
Published product information is shown below. Confirm the offered model, dimensions, ratings and mating interfaces against the approved drawing and purchase specification before ordering.
| Product | GN19-12(C) Indoor AC Disconnect Switch |
|---|---|
| Category | Indoor Disconnect & Earthing Switches |
| Representative range / models | GN19-12 and GN19-12C; 400–1,250 A |
| Standards / reference basis | Catalogue ratings and project requirements confirmed by KOVYEL before supply |
| Typical applications | Indoor medium-voltage switchgear isolation; Panel refurbishment requiring matched GN19 interfaces |
| Rated voltage | 12 kV |
| Rated current | 400, 630, 1000 or 1250 A |
| Short-time withstand current | 12.5, 20 or 31.5 kA |
| Peak withstand current | 31.5, 50 or 80 kA |
| Configuration | Standard and C-type arrangements |
| Pole and terminal dimensions | Selected by model and switchgear layout |
| Final dimensions and ratings | Confirmed against the approved drawing, equipment interface and project specification |
| Supply basis | Project-specific RFQ, coordinated documentation and export packing |
Unverified dimensions or performance ratings are not published as fixed values. Submit the controlling drawing or requirement schedule for final confirmation.
Standard and C-type arrangements checked against the panel drawing
Continuous-current and withstand requirements reviewed together
GN19-12(C) indoor disconnect switches provide manual isolation in 12 kV switchgear, with standard and C-type arrangements listed in the catalogue. Current and withstand ratings depend on the exact model; confirm pole spacing, terminal connections, operating mechanism and interlocks against the approved switchgear drawing.
Use the following product-specific inputs in the technical clarification and identify the controlling drawing revision for GN19-12(C) Indoor AC Disconnect Switch.
| Item | Information for technical approval |
|---|---|
| 01 | Standard or C-type GN19 configuration |
| 02 | Model-specific current and withstand requirements |
| 03 | Pole spacing and terminal connections |
| 04 | Operating mechanism, interlocks and cabinet drawing |
State the exact switch reference, operating arrangement and supplied accessories. Identify mechanisms, interlocks, support parts and terminal connections item by item. Clarify panel or structural work and site services separately from the equipment supply.
Include the required equipment data sheet, layout, terminal drawing and operating/interlock schedule. State the specified electrical duties and acceptance records, then confirm the offered configuration and document availability before purchase.
Align equipment and mechanism identification with the project tags. Specify how linkages, handles, terminals and other separately packed parts should be marked and reconciled.
Confirm the exact model, current and withstand duties, terminal geometry, mechanism, interlocks and installation layout against the approved specification as well as the voltage requirement.
Use the exact offered model and project BOQ item, with the approved drawing revision, required quantity and destination. Include the product-specific approval inputs above and identify any separately requested accessories or documents.
Concise catalogue facts for model comparison, product matching and AI-assisted technical research.
GN19-12 and GN19-12C are indoor 12 kV AC disconnect-switch configurations. The published current options span 400–1,250 A; panel geometry and required withstand duty must match the selected model.
Do not assume interchangeability. Confirm pole and terminal dimensions, operating linkage and the approved panel drawing, as well as current and withstand requirements.
The published range is GN19-12 and GN19-12C; 400–1,250 A. Confirm the exact offered model and its applicable ratings rather than combining limits from different configurations.
For a matched quotation, provide: Standard or C-type GN19 configuration; Model-specific current and withstand requirements; Pole spacing and terminal connections; Operating mechanism, interlocks and cabinet drawing; Quantity by model, destination, drawing revision and required inspection documents.
A complete RFQ helps KOVYEL confirm the product configuration, production basis, documentation, export packing and delivery proposal without repeated clarification.
Send the technical documents with the form below. KOVYEL will review the product interface, required standard, quantity and destination before preparing the quotation.
EQUIPMENT SELECTION
Compare published functions, ratings and quotation inputs. Final selection requires the specified voltage, current or capacity, installation conditions and equipment interfaces.