Overhead line equipment supply for EPC contractors
info@kovyel.com EN FR AR
KOVYEL · CABLE FIXING CLAMPS & SUPPORTS JGW, JGH & JGP Cable Fixing Clamps
PROJECT-MATCHED OVERHEAD LINE EQUIPMENT

JGW, JGH & JGP Cable Fixing Clamps

Cable Fixing Clamps & Supports · Drawing-confirmed project supply

KOVYEL JGW, JGWD, JGH and JGP cable fixing clamps secure single or trefoil power cables in substations, tunnels and cable supports. Aluminium and glass-fibre SMC bodies cover cable outside diameters from 28 to 210 mm.

Drawing-Matched Project RFQ Supply JGW, JGWD, JGH, JGP and JGPD dimensional tables and cable data confirmed by KOVYEL
Product categoryCable Fixing Clamps & Supports
Representative rangeJGWD-3/4
Technical basisJGW, JGWD, JGH, JGP and JGPD dimensional tables and cable data confirmed by KOVYEL
Supply modeProject quotation / coordinated supply
PRODUCT OVERVIEW

JGW, JGH & JGP Cable Fixing Clamps: product overview

KOVYEL JGW, JGWD, JGH and JGP cable fixing clamps secure single or trefoil power cables in substations, tunnels and cable supports. Aluminium and glass-fibre SMC bodies cover cable outside diameters from 28 to 210 mm.

KOVYEL confirms final selection against the approved drawing, interface dimensions, service conditions and purchase specification before quotation and supply. Catalogue references define the product family; the approved project documents remain the controlling basis.

PRODUCT IMAGES

Review the available construction and product views.

Images show representative configurations. Final construction, marking and packing are confirmed against the approved project documents.

TECHNICAL & PROCUREMENT DATA

Published specifications and model selection

Published product information is shown below. Confirm the offered model, dimensions, ratings and mating interfaces against the approved drawing and purchase specification before ordering.

ProductJGW, JGH & JGP Cable Fixing Clamps
CategoryCable Fixing Clamps & Supports
Representative range / modelsJGWD-3/4; JGH-01 to JGH-7; JGW-01 to JGW-10; JGP-01 to JGP-10; JGPD and related SMC models
Standards / reference basisJGW, JGWD, JGH, JGP and JGPD dimensional tables and cable data confirmed by KOVYEL
Typical applicationsSingle power cable fixing; Trefoil cable support; Cable tunnel and tray installations; High-voltage cable restraint
JGWD80-125 mm cable outside diameter; two single-cable sizes
JGH40-210 mm cable outside diameter; JGH-01 through JGH-7
JGW aluminium28-160 mm cable outside diameter; JGW-01 through JGW-6
JGP trefoil30-160 mm cable outside diameter; JGP-01 through JGP-10
JGW SMC28-200 mm cable outside diameter; JGW-1 through JGW-10
JGPD SMC trefoil45-180 mm cable outside diameter; three-cable arrangement
Final dimensions and ratingsConfirmed against the approved drawing, equipment interface and project specification
Supply basisProject-specific RFQ, coordinated documentation and export packing

Unverified dimensions or performance ratings are not published as fixed values. Submit the controlling drawing or requirement schedule for final confirmation.

TYPICAL APPLICATIONS

Where this product family is typically used.

01

Single power cable fixing

Aluminium-alloy and SMC body options

02

Trefoil cable support

Single and trefoil cable forms

03

Cable tunnel and tray installations

Insulating liner options

04

High-voltage cable restraint

28-210 mm cable outside-diameter coverage

SELECTION & PROCUREMENT

From technical approval to a defined supply scope.

For purchasing teams and project engineers: confirm the exact JGW, JGH & JGP Cable Fixing Clamps configuration, included components and required acceptance documents before comparing quotations.

JGW, JGH & JGP Cable Fixing Clamps: cable layout, restraint and support approval

Use the following product-specific inputs in the technical clarification and identify the controlling drawing revision for JGW, JGH & JGP Cable Fixing Clamps.

ItemInformation for technical approval
01Exact offered model and purchase or BOQ item for JGW, JGH & JGP Cable Fixing Clamps, with the required drawing or specification revision.
02Cable outside diameter, count and actual support or restraint arrangement.
03Mounting dimensions, support spacing and required duty.
04Liners, fixings, installation instructions and configuration-specific acceptance evidence.

Define the BOQ supply scope

Specify the actual cable layout and the exact cleat and fixing arrangement. Separate single, trefoil, quad and multicore configurations in the BOQ. List liners, bolts, support channels and mounting accessories explicitly and clarify whether each offer covers a cleat alone or the complete installed fixing set.

Technical submittals and inspection requirements

Provide cable outside diameters, the support drawing, spacing and project restraint requirements. Request the offered cleat drawing, installation and tightening instructions and applicable acceptance records. Where short-circuit performance or IEC 61914 compliance is required, confirm the tested cable layout, fixing spacing, supporting structure and exact offered configuration; a catalogue title alone does not establish that performance.

Packing, identification and delivery

Identify cleats by model, cable layout, size and BOQ item. Keep liners and matched fasteners identifiable, and reconcile the quantity by support location and separately ordered spare parts.

Quotation and order planning

Send quantities by exact model and configuration, destination, requested delivery date and required quotation terms. Identify complete assemblies, loose components and spares separately. Ask the quotation to confirm minimum order quantity where applicable, delivery proposal, packing, inspection documents and any phased-shipment requirements. Agree the actual commercial and documentation scope before order release.

Buyer questions

Can short-circuit suitability be established from cable diameter alone?

No. The project design must also establish the required duty, cable layout, cleat spacing, fixing arrangement and supporting structure. Review applicable test evidence for the exact proposed configuration.

How should JGW, JGH & JGP Cable Fixing Clamps be identified in the RFQ?

Use the exact offered model and project BOQ item, with the approved drawing revision, required quantity and destination. Include the product-specific approval inputs above and identify any separately requested accessories or documents.

Related selection resources

Send the BOQ and drawings for quotation

PRODUCT SELECTION SUMMARY

JGW, JGH & JGP Cable Fixing Clamps: key facts for technical buyers.

Concise catalogue facts for model comparison, product matching and AI-assisted technical research.

What is JGW, JGH & JGP Cable Fixing Clamps?

KOVYEL JGW, JGWD, JGH and JGP cable fixing clamps secure single or trefoil power cables in substations, tunnels and cable supports. Aluminium and glass-fibre SMC bodies cover cable outside diameters from 28 to 210 mm. The listed range is JGWD-3/4; JGH-01 to JGH-7; JGW-01 to JGW-10; JGP-01 to JGP-10; JGPD and related SMC models.

Which models or ratings are covered?

The published KOVYEL range is JGWD-3/4; JGH-01 to JGH-7; JGW-01 to JGW-10; JGP-01 to JGP-10; JGPD and related SMC models. Final configuration is confirmed against the required electrical, mechanical and dimensional data.

What information is needed to select JGW, JGH & JGP Cable Fixing Clamps?

For a matched quotation, provide: Required JGW, JGH, JGP or related model, single or trefoil arrangement and quantity; Actual cable outside diameter, cable count and cable construction; Mounting surface, fixing-hole pattern, support spacing and installation drawing; Required restraint duty, project short-circuit forces and test documentation; Body material, liner, installation orientation and environmental requirements; Required project standards and test documents, destination and delivery schedule.

QUOTATION CHECKLIST

Send these details for an accurate offer.

A complete RFQ helps KOVYEL confirm the product configuration, production basis, documentation, export packing and delivery proposal without repeated clarification.

01Required JGW, JGH, JGP or related model, single or trefoil arrangement and quantity
02Actual cable outside diameter, cable count and cable construction
03Mounting surface, fixing-hole pattern, support spacing and installation drawing
04Required restraint duty, project short-circuit forces and test documentation
05Body material, liner, installation orientation and environmental requirements
06Required project standards and test documents, destination and delivery schedule

Have a BOQ, drawing or equipment schedule?

Send the technical documents with the form below. KOVYEL will review the product interface, required standard, quantity and destination before preparing the quotation.

Send Project RFQ →

PRODUCT AND INTERFACE SELECTION

Compare cable fixing and restraint arrangements.

Choose single-cable or trefoil support from the cable outside diameter, arrangement and mounting drawing. Confirm the specified fault duty and supporting test evidence before setting the clamp type or installation spacing.

PROJECT INQUIRY

Request a quotation for JGW, JGH & JGP Cable Fixing Clamps

Inquiry scope: JGW, JGH & JGP Cable Fixing Clamps

Add technical details (optional)